Surface preparation
Fluiglide should be applied over the top of one of the following systems, taking care to observe over-coating time limits:1. Where repairs to corrosion damaged equipment need to be carried out first, full 200 series application should take place with the exception of 252 which should be substituted with two coats of Fluiglide.2. Where new or undamaged equipment is to be coated, 2 or 3 coats of 232 application should be carried out to a minimum dft of 14 mils (350 microns) in light corrosiveenvironmentor 4 to 5 coats of 232 to a minimum dft of 24 mils (600 microns) in a highly corrosive environment.3. Pipe work should be Fluiglided by application over a single coat of Polyglass PG where centrifuging is the application method, or over two spray applied coats of Polyglass where spray is the application method. Minimum dft’s should be 24 mils and 30 mils (600 and 750 microns) respectively.Heat should not be used to cure these systems when used as undercoats for Fluiglide in pipe work (except in very cold conditions), but good ventilation through the pipe should be achieved.4. Where Fluiglide is to be used on concrete, the concrete should be primed using one of the concrete priming systems specified on User Information Sheet
CP1 before coating with Fluiglide, but where the environment is aggressive, priming and one coat of Polyglass to a minimum of 24 mils (600 microns) should be carried out before Fluigliding.
Mixing ratio / mixing
100:2 parts by weight, base to catalyst.
Mixing
Simply add correct amount of catalyst to Fluiglide and stir with a mechanical stirrer to ensure complete mixing. Where inhibitor is added, it is imperative that this is added to Fluiglide and the material allowed to stand for at least 5 minutes before the catalyst is added.
Pot life
Standard Fluiglide: 20 to 30 minutes at 68°F (20°C). With inhibitor: 40 to 45 minutes at 68°F (20°C) for spray application.
Thinners
Under no circumstances must this product be diluted or thinned. PG grade is available for lower viscosity applications. Standard Fluiglide and Fluiglide PG can be mixed for finer adjustments of viscosity.
Packaging
1 and 5 gallon kits including catalyst.
Storage life
12 months stored at temperatures below 68°F (20°C).
Catalyst type
Methyl ethyl ketone peroxide (Corrocoat Type P2).
Overcoating
Minimum 6 hours. Maximum 24 hours at 68°F (20°C). Temperature variable.
Cure time
Minimum service time 48 hours. For potable water 7 days at a minimum of 45°F (7°C). Full chemical cure 8 days at lowambient of 50°F (10°C).
Cleaning solvent
Acetone, methyl ethyl ketone.NOTE: This coating is intended to increase fluid flow efficiency. Often it will be necessary to take into consideration design parameters, particularly on pumping equipment which is multi-stage or has narrow passageways. In order to obtain benefit while maintaining maximum flow conditionin some types of pump, it will be necessary to leave impeller passageways uncoated.