Product reference:
Product title:
Valid from:
Last reviewed:
Type
As a primer for concrete surfaces that are damp, or where levels of moisture are approaching the saturation point of concrete.
WCP is designed for application to concrete surfaces with high moisture level. It shouldNOTbe applied when surface water is apparent.
Before handling or using this product, the material safetydata sheet should be read, and all precautions observed.
Mechanical abrasion of the surface is required to provide a physical “key” for the product to adhere to, prepare the surface of the concrete. Refer to data sheet SP5.
Airless pump of minimum 30:1 ratio is recommended with 10mm diameter (3/8”) nylon lined hose.
Seals should preferably be of leather and PTFE and all fluid filters removed.Tip size 18 thou to 30 thou with reverse clean and a 45° fan pattern. Size of tip and fan pattern willvary dependent upon the nature of the work.Pressure to suit hose lengths and working conditions. (circa 200bar). Brush and roller may also be used.
Apply a single coat to a wet film thickness of between4-6 mils (100-150 microns). Over thickness will considerably increase tack free time and substantial over thickness is detrimental. The initial cure of this product is partially by air-drying and for this to occur it is essential that good ventilation is achieved. This primer is designed for use on concrete surfaces. WCP primer should not be used at temperatures below 41°F (5°C) unless specifically made for low temperature application.
Clear/slightly amber liquid.
250-400 sf per gallon at 4-6 mils dft (6-10 M2/Litre at 100-150 microns).
This material contains volatile liquid convertible to solids. Volume solids obtained will vary dependent upon polymerization conditions. Nominally 92% of the contents are convertible to solid.
Concrete: Approximately 200-280 sf per gallon at 4-6 mils dft (5-7 M2/Litre at 100-150 microns WFT). NOTE: This information is given in good faith, but rate may vary significantly, dependent upon environmental conditions, the geometry, nature of work undertaken and the skill and care of application. Corrocoat accepts no responsibility for any deviation from these values
1.15 mixed.
78°F (26°C)
DFT is not specified. Wet film thickness should be checked and be within the range 4-6 mils (100-150 microns) during application.
98:2 base to hardener weight/weight.For temperatures below 64°F (18°C) add catalyst to base and mix vigorously with a mechanical stirrer for not less than 2 minutes. At temperatures above 64°F (18°C), first add retarder and stir with mechanical stirrer for 2 minutes. Allow 5 minutes before the addition of the catalyst stirred as above. Adding retarder after the catalyst will ruin the product.Procedures for spray application are similar to those for Polyglass, the Polyglass application data sheet should be read before the mixing of this product.
1 Gallon and 5 Gallon kits.
Base 1 year, Hardener 6 months, in unopened drums which should be stored below 75°F (24°C), away from heatsources and direct sunlight.
Methyl Ethyl Ketone Peroxide, special blend Type P3.
3:2 parts by weight base to activator.
Tack-free 90 minutes, 50°F at 4 mils (10°C at 100 microns WFT). Tack-free 45-60 minutes, 68°F at 4 mils (20°C at 100 microns WFT).
Depending on temperature and ventilation, this product is designed to be applied to concrete with high relative humidity level. Overcoating as per data sheet SP5.
Methyl Ethyl Ketone before gelation.
Variable dependent upon temperature, but approximately 2 hours at 50°F (10°C), 1 hour at 68°F (20°C).
The use of thinners with this product is detrimental to its performance. This product should not be diluted or thinned, refer to Corrocoat technical sources for more information.