A Race Against the Clock

Jul 21, 2020 | Uncategorized | 0 comments

A shipping company asked Corrocoat Hellas to repair and refurbish a 900mm diameter condenser tube cover where an epoxy coating had failed. The cover was abrasive blast cleaned in accordance with ISO8501-1 Sa2½, high pressure water washed and then blasted for a second time to ensure the full removal of the original coating. This revealed significant corrosion and meant a rebuild of the cover and division plates was required. This work was completed using laminating techniques and Corroglass 600 series materials.